A DISCUSSION ON IP INTERMEDIATE-GRADIENT ηs CURVE UNDER THE CONDITION OF NON-HORIZONTALUNIFORM POLARIZATION |
Dai Xueli |
810 Party of East China Geological Exploration Cororation, China National Nonferrous Metals Industry Corporation |
|
|
Abstract In practical work, the relative position between the blind orebody and thetwo power-supply electrodes of the intermediate-gradient facility not distant fromthe orebody frequently makes the blind orebody somewhat under the conditionof non-horizontal uniform polarization. This causes the obtained ηs curve and theconnections of the ηs curve formed by movement of the power-supply electrodesto be distorted to some extent.Through simulating the usually-adopted IPintermediate-gradient facilityand taking volume polarization as an example,the present paper makes an ana-lysis and discussion on the above-mentioned distortion by calculating the inter-mediate-gradient ηs curve and its connections with the formula of point powersource. In addition, it mentions some problems that are worth noticing in proces-sing observed intermediate-gradient ηs data and gives some viewe on IP ηs full-field measurement technique that deserves popularization.
|
Published: 24 August 1986
|
|
|
|
[1] |
ZHANG Si-Wei, WU Rong-Xin, HAN Zi-Ao, WU Hai-Bo. The application of bilateral filtering to denoise processing of ground penetrating radar data[J]. Geophysical and Geochemical Exploration, 2021, 45(2): 496-501. |
[2] |
LI Jing-Xiang, ZHAO Ming, LAI Hao, XIONG Shuang-Cheng, TANG Yang. Imaging detection and recognition technology of underground cable based on ground penetrating radar[J]. Geophysical and Geochemical Exploration, 2020, 44(6): 1482-1489. |
|
|
|
|