Applied processing for calculation of TEM in-loop full-zone apparent resistivity and 1-D inversion of field transferred from dB/dt response observed directly
JIANG Bang-Yuan, DU Qing-Feng
Institute of Geophysical and Geochemical Exploration,CAGS,Langfang 065000,China
Abstract:The voltage response(dB/dt)is wildly used in TEM in-loop configuration; nevertheless, for layered earth,it has several defects in solution, such as unique valued, dual-valued, undefined valued and overshoot and undershoot phenomena. It is hoped that field response has not these defects. So if we want to observe field response directly,SQUID or flux-gate sensor should be added. Therefore the process of transferred dB/dt should be available. Of course it has some other difficult problems in calculation, for examples: how to get the first electromagnetic field strength and applied apparent depth formula. This paper tackles those problems and has solved them.
蒋邦远, 杜庆丰. TEM中心回线电动势响应换算磁场响应求解全区视电阻率及1-D直接反演的实用方法[J]. 物探与化探, 2017, 41(4): 758-768.
JIANG Bang-Yuan, DU Qing-Feng. Applied processing for calculation of TEM in-loop full-zone apparent resistivity and 1-D inversion of field transferred from dB/dt response observed directly. Geophysical and Geochemical Exploration, 2017, 41(4): 758-768.
[1] Levy G M. Correction of measured transient electromagnetic response for finite transmitter turn-off Duration[J].Technical Note TN-16, Geonics Ltd,1984. [2] Spies B R, Eggers D E. The use and misuse of apparent resistivity in electromagnetic methods [J]. Geophysics,51(7). [3] 蒋邦远.实用近区磁源瞬变电磁法勘探[M].北京:地质出版社,1998. [4] 蒋邦远.磁源TEM测深一维反演经验式及应用效果[J].物探与化探,2000,29(2):99-104. [5] 白登海.瞬变电磁法中两种关断电流对响应函数的影响及其应对策略[J].地震地质,2001,23(2): 245-251. [6] 杨云见,王绪本,何展翔.瞬变电磁法中的斜阶跃波效应及常规的几种校正方法分析[J].物探化探计算技术,2006,28(2):129-132. [7] 陈明生,田小波.电隅源瞬变电磁测深研究(五)——实测感应电压转换成垂直磁场[J].煤田地质与勘探,1999,27(5):63-64. [8] 罗国平,魏凤英.瞬变电磁法磁场及视电阻率研究[J].中国煤田地质,2000,12(2):60-62.