Abstract The bearing capacity of the prefabricated pile obtained by the high strain method is not entirely correct. In
obtaining accurate bearing capacity, fitting parameters are not necessarily confined in the provided range. The high strain curve
should be explained on the basis of the fitting parameters determined by such factors as the parameters of the prefabricated
pile, the construction technology and the engineering properties of soil. Only in this way can real bearing capacity be obtained.
|