ZHOU Neng1(), DENG Ke-Qing2(), ZHUANG Wen-Ying3
1. Institute of Acoustics, Chinese Academy of Sciences, Beijing 100190, China 2. Shanghai Hexu Information Technology Company,Beijing 100102,China 3. School of Information Management, Beijing Information Science and Technology University,Beijing 100192,China
Multi-channel gamma-ray spectrometers are necessary for measuring natural and artificial radionuclides. The core of the multi-channel gamma-ray spectrometers is the multi-channel pulse amplitude analysis, which determines the resolution and analysis accuracy of radionuclides. This study introduces the working principle of a multi-channel pulse amplitude analyzer based on linear discharge and describes the methods for analyzing pulse amplitude and obtaining spectrum peaks. Secondly, this study details the design methods of eight important parts of the multi-channel pulse amplitude analyzer, including the design basis, design idea, and feasible schemes. Finally, this study details the logical sequence diagram of the analyzer, laying a foundation for readers to design a multi-channel pulse amplitude analyzer. Using the working principle, design method, and working logic sequence diagram presented in this paper, as well as modern high technology, readers can develop a new type of modern multi-channel pulse analyzer with uniform channel width, excellent differential nonlinearity, and improved resolution of radionuclides, thus better serving the society using gamma-ray spectrum data with higher energy resolution and high measurement accuracy.
Zhou X H, Qiao G Z. The introduction and application of the new generation airborne multi-channel gamma spectrometer[J]. Geophysical and Geochemical Exploration, 2002,26(4):318-320.
[2]
International Atomic Energy Agency. Guidelines for radioelement mapping using gamma ray spectrometry data [R]. IAEA-TECDOC-1363, 2003.
Mi Y H, Zhou X H, Jiang Z X, et al. Design of multi-channel pulse amplitude analyzer based on interleaved sampling technology[J]. Nuclear Electronics & Detection Technology, 2014,34(12):1469-1473.
Lai W C, Ge L Q, Wu Y P, et al. A new portable multi-channel γ spectrometry based on inserted PC104 computer[J]. Nuclear Electronics & Detection Technology, 2004,9(1):37-40.
Jiang Z C, Fang F, Ding W C, et al. A design of hand-held gamma spectrometer with low power consumption[J]. Nuclear Electronics & Detection Technology, 2008(11):1223-1225.
Wang P, Zhou X H, Jiang Z X, et al. The design of gamma-ray spectrometer based on digital pluse amplitude analyzer[J]. Geophysical and Geochemical Exploration, 2013,37(2):291-294.
Zeng G Q, Ge L Q, Xiong S Q, et al. The application of digital spectroscopic technique to airborne gamma-ray investigation[J]. Geophysical and Geochemical Exploration, 2010,34(2):209-213.
Wang Y, He K Z, Huang S, et al. Design of multichannel pulse amplitude analyzer based on FPGA[J]. Nuclear Electronics & Detection Technology, 2005,35(4):416-419.
[11]
屈建石, 王晶宇. 多道脉冲分析系统原理[M]. 北京: 原子能出版社, 1987.
[11]
Qu J S, Huang J Y. Principle of multi-channel pulse analysis system [M]. Beijing: Atomic Energy Press, 1987.
[12]
王经瑾, 范天民, 钱永庚, 等. 核电子学[M]. 北京: 原子能出版社, 1985.
[12]
Wang J J, Fan T M, Qian Y G, et al. Nuclear electronics [M]. Beijing: Atomic Energy Press, 1985.
Wu Y P, Lai W C, Ge L Q, et al. A new spectrum stabilization technique in portableγ-ray spectrometry[J]. Geophysical and Geochemical Exploration, 2003,27(2):131-134.
[14]
庞巨丰. γ能谱数据分析[M]. 西安: 陕西科学技术出版社, 1990.
[14]
Pang J F. γ energy spectrum data analysis [M]. Xi’an: Shaanxi Science and Technology Press, 1990.
[15]
何为民, 奚大顺. 智能放射性勘查仪器[M]. 北京: 原子能出版社, 1994.
[15]
He W M, Xi D S. Intelligent radio-logical survey instrument [M]. Beijing: Atomic Energy Press, 1994.