THE EXPERIMENT AND DISCUSSION ON SAFE SEPARATION BETWEEN MAGNETOMETER PROBES |
GUO Ying1, WANG Yuan-qing2, FAN Zhi-xiong3, WANG Chuan-lei4, LIU Chao4 |
1. Geophysical Exploration Party of Henan Bureau of Geo-exploration and Mineral Development, Zhengzhou 450053, China;
2. Geophysical Exploration Party of China National Salt Industry Corporation, Changsha 446000, China;
3. Wuhan Geophysical and Geochemical Exploration Company of State Bureau of Metallurgical Industry, Wuhan 430074, China;
4. Institute of Geophysics and Geomatics, China University of Geosciences, Wuhan 430074, China |
|
|
Abstract In order to improve the management of magnetic prospecting, ensure the quality of field work and adapt the management to the development of science and technology, especially to the improvement and enhancement of magnetic instruments, it is necessary to make timely revision of the relevant technical regulations or operational standards, which should agree with the actual conditions. It means that the regulations should be clearly determined and easily executed by subordinate production units. This paper discusses the safety separation distance between probes during the noise testing of magnetometers before the operation mentioned in "Technical Regulations of High Precision Grounded Magnetic Measurement" based on certain detailed field experiments. In combination with related technical regulations and the requirements of the textbooks as well as special test results, the authors propose some suggestions for revising the above regulations after the comparison and analysis of the results.
|
Received: 12 April 2012
Published: 10 December 2012
|
|
|
|
|
|
|
|