Abstract:Central-loop TEM sounding was carried out three times, and TEM soundings over the buried goaf was interpreted. The interpretation results show that the limits of the goaf are enlarged with time. The surface sink and the cracks detected demonstrate that the power building is in an unstable state. With the transient electromagnetic method, we can rapid obtain the electric information of strata in shallow or even great depth, interpret geological problems ideally, and get satisfactory detection result.
[1] 牛之琏.时间域电磁法原理[M].长沙:中南大学出版社,2007.[2] 方文藻.瞬变电磁法测深原理[M].西安:西北工业大学出版社,1993.[3] 李貅.瞬变电磁测深的理论与应用[M].西安:陕西科学技术出版社,2002.[4] 米萨克 N· 纳比吉安.勘察地球物理电磁法第一卷理论[M].赵经祥,王艳君,译. 北京:地质出版社,1992.[5] 考夫曼 A A,凯勒 G V.频率域和时间域电磁测深[M].北京:地质出版社,1987:2-3,145-147,224.[6] Xue G Q,Bai C Y,Yan S.Study on Large scale loop source TEM method for deep sounding [J].Journal of Applied Geophysics,2012,76:23-32.[7] 李耀华,杨进,李世峰.瞬变电磁与电阻率测深在沙午铁路采空区勘查中的应用[J].物探与化探,2011,35(2).[8] Taylor K, Widmer M, Chesley M.Use of transient electromagnetic to define local hydrogeology in an arid alluvial environment[J].Geophysics,1992,57:343-352.[9] Baumgartner F.A new method for geological investigations underwater [J].Geophysical Prospecting,1996(4):71-98.