地震勘探节点采集系统设计的要点
岩巍

Key points of the design of a nodal acquisition system for seismic exploration
YAN Wei
表2 地震仪器等效输入噪声
Table 2 Equivalent input noise of seismic instruments
采样间隔/ms 前放增益/dB 最大等效输入噪音/μV
A级 B级 C级
0.25 0 ≤5 ≤20 ≤60
12 ≤1 ≤5 ≤15
24 ≤0.4 ≤1.3 ≤4
36 ≤0.1 ≤0.5 ≤1
0.5 0 ≤0.8 ≤3 ≤3
12 ≤0.2 ≤0.8 ≤1.5
24 ≤0.1 ≤0.35 ≤0.6
36 ≤0.06 ≤0.3 ≤0.5
1 0 ≤0.5 ≤2 ≤3
12 ≤0.15 ≤0.6 ≤0.75
24 ≤0.05 ≤0.2 ≤0.36
36 ≤0.04 ≤0.15 ≤0.3
2 0 ≤0.4 ≤1.5 ≤1.6
12 ≤0.1 ≤0.4 ≤0.45
24 ≤0.05 ≤0.2 ≤0.25
36 ≤0.04 ≤0.13 ≤0.22
4 0 ≤0.5 ≤1 ≤1.5
12 ≤0.07 ≤0.3 ≤0.4
24 ≤0.04 ≤0.15 ≤0.2
36 ≤0.03 ≤0.1 ≤0.15