X荧光快速测量在松桃大路锰矿勘查中的应用
刘松

The application of X-ray fluorescence rapid measurement to the exploration of the Dalu manganese deposit in Songtao
Song LIU
表3 ZK103钻孔岩心、副样手持X荧光测量锰含量与化验成果对照
Table 3 Comparison of manganese content measured by hand-held X-ray fluorescence in core and accessory sample of ZK103 bore with laboratory results
化验号 X荧光测量结果 化验室结果
岩心Mn含量/% 几何平均Mn含量/% 副样中Mn含量/% Mn含量/%
H29 0.92~4.15 1.98 2.36 1.72
H28 10.06~18.85 15.74 14.81 14.12
H27 2.52~8.58 3.06 4.99 3.87
H26 12.63~19.74 16.43 15.13 16.93
H25 17.56~21.45 18.01 19.65 18.62
H24 17.78~18.63 18.15 16.78 16.15
H23 17.64~19.23 20.18 21.56 19.23
H22 18.85~22.98 21.08 21.42 20.29
H21 19.76~22.65 19.87 19.87 20.82
H20 19.55~23.06 22.16 22.16 22.06
H9 20.45~24.24 22.46 22.46 21.26
H8 23.18~26.79 28.11 28.11 24.62
H7 25.87~30.15 28.01 28.64 26.87
H6 14.65~30.23 22.44 19.12 18.08
H5 30.25~36.04 34.04 29.59 27.09
H4 15.48~27.65 18.56 16.89 17.35
H3 27.65~30.12 28.88 25.15 24.31
H2 23.12~11.87 17.49 16.86 16.06
H1 1.45~7.73 3.59 2.93 1.76